Semi-rigid, dual wall heat shrink tubing designed to seal & environmentally protect splices in the most demanding applications.

Features and Benefits

  • Environmentally seal and protect splices and terminals in automotive, on highway/off road heavy equipment applications
  • Highly resistant to Diesel and other common automotive fluids and solvents
  • Semi-rigid and mechanically tough outer jacket provides added strain relief and excellent abrasion protection
  • Thick adhesive liner forms an effective barrier against fluids and moisture penetration
  • Shrink ratio allows for fewer sizes to cover numerous splice configurations and diameters
  • Shrink ratio: 4:1
  • Continuous operating temperature: -40°C to 130°C
  • Shrink temperature: 130°C

Standards

  • UL 224 125°C – UL file # E63390
  • Approved to all major Automotive OEM splice sealing specifications

Typical Applications

Environmental sealing of in-line splices, connectors & terminals, strain relief, abrasion protection and electrical insulation, on-highway and off-road heavy equipment, fleet & marine sealing & protection

Market/Applications

  • Dual Wall
  • Splice Sealing Solutions
  • Automotive

** Reference fuel C, ASTM IRM 903, Diesel #2 Fuel @60C for 24hrs

Ordering

Select a dimension which will shrink snugly over the component to be covered. If recovery is restricted the resultant wall thickness will be less than specified.

  • Select Options:
    • Color: Black (BK)
    • Length: Standard cut length, 4 ft stick or spool
  • Please specify the product name plus the options you require
  • Order Example: CDR 3, black, 65 mm length

Please contact your Customer Service Representative for information on custom sizes, lengths and material data sheet.

Installation

  • DSG-Canusa offers a comprehensive selection of technically advanced shrink appliances that ensure process stability and repeatability
  • Minimum recovery temperature: 125°C
  • Adhesive activation temperature: 110°C
  • Use with DERAY®-FST shrink ovens for best performance
    Ordering
  • Select a dimension which will shrink snugly over the component to be covered. If recovery is restricted the resultant wall thickness will be less than specified.
Order NumberExpandedRecoveredCut Lengths
Internal Diameter (Min) DInternal Diameter (Max) dTotal Wall Thickness (Nom) W
mminmminmminmmin
160.2361.270.0501.270.050501.97
280.3151.520.0601.520.060501.97
3120.4722.030.0801.910.075652.56
4180.7103.810.1502.410.095752.95