CT 50N Series

Heat shrink terminations for single and three core, 5 kV through 8 kV XLPE and EPR non-shielded cables for the Utility and Construction markets

Features and Benefits

  • Fast, consistent installation means lower installed costs
  • Installation environment: use of torch adds flexibility to cable preparation in any climate
  • Heat activated sealant for weather tight seals
  • Light weight construction requires no additional support
  • UV resistant, non-tracking outer tube for long life even under adverse conditions. No sheds are required for outdoor use
  • Tough abrasion resistant outer covering
  • Slim profile allows installation in confined switch gear cubicles

Product Line

CT 50N Series

  • 1/C, 5 – 8 kV non-shielded extruded dielectric (XLPE or EPR) fixed power cable terminations. They are available as three each single core kits per box for XLPE and EPR insulated cables.

CT 50N3 Series

  • 3/C, 5 – 8 kV non-shielded extruded dielectric (XLPE or EPR) fixed power cable terminations. They are available in one, three core kit per box. As an option, the 1/C, CT 50N series kits can be converted to 3/C kits by purchasing a CT3M0DA or CT3M0DB conversion kit. The following is the selection criteria for the 3/C conversion kits:

Market/Applications

  • Water/Waste Water Treatment
  • Shipboard
  • Generation
  • Power Distribution
  • Industrial
  • Petrochem/Pulp & Paper
  • Power Distribution – MV
  • Utility
  • OIl & Gas
  • Energy
  • Mining

Ordering

  • Select the termination kit size for the non-shielded cable to be terminated.
  • Confirm that the minimum and maximum cable dimensions are not exceeded. When at the high end of the conductor range it may be necessary to select the next larger kit size. Size range dimensions are based on the cable dimensions in the ICEA cable standards.
  • To include a cable preparation kit with the termination kit, add the suffix to the end of the order number. FOR EXAMPLE: a 5 kV termination for 2/0 cable with a cable preparation kit would be CT 51NP.
Indoor/Outdoor Kit Order Number Conductor Size Range Insulation Diameter (min) Jacket Diameter (max) Standard package
in mm in mm Kits/Box
1/C Cable, 5 – 8 kV
CT 51N #4 – 2/0 AWG 0.40 10 0.94 24 3 – 1/C
CT 52N 3/0 – 500 kcmil 0.70 18 1.30 33 3 – 1/C
CT 53N 750 – 1500 kcmil 1.10 28 2.15 55 3 – 1/C
3/C and 3/C Armored Cable, 5 – 8 kV
CT 51N3 #4 – 2/0 AWG 0.40 10 3.00 76 1 – 3/C
CT 52N3 3/0 – 500 kcmil 0.70 18 3.31 84 1 – 3/C
CT 53N3 750 – 1500 kcmil 1.10 28 5.00 127 1 – 3/C